Physical Infrastructure & Electrical

The wire, the rack, the power and the room behind every system.

Built for construction teams, facilities managers and anyone planning an office move who needs solid physical groundwork.

Rack Elevation, IDF-2

Interactive

Rack elevation of a network closet containing a Cat6A patch panel, two core switches, an edge firewall pair, a fiber enclosure, a console and out-of-band unit, database and application servers, a storage array and a rack UPS. Select any device with the keyboard or a pointer to read what it connects to, its power feed and the work ACG does around it.

Selected Device

Select a Device

Hover, tap or focus a device in the rack to see what it does and what ACG installs around it.

Connects To
Not selected
Power Feed
Not selected
What ACG Does
Not selected
  • Labeled low-voltage cabling terminated in a wiring rackTermination
  • Network cables plugged into a switch with link lights litSwitch Uplinks
  • Technician working inside a commercial electrical panelPanel Work
  • Long row of equipment cabinets in a data roomEquipment Row

Structured Cabling & Fiber

Category 6A horizontal cabling for 10GBASE-T channels up to 100 meters, and Category 6 where channel length, installation and testing support the application, all installed to ANSI/TIA-568 practice. Single-mode and multimode fiber backbones connect the main and intermediate distribution frames. Pathways, firestopping and bend radius are planned before the first cable is pulled, so the plant has room for the next upgrade.

  • Cat6 and Cat6A Horizontal Runs
  • OM3/OM4 Multimode and OS2 Single-Mode Fiber
  • Pathway and Firestop Planning
  • As-Built Drawings and Cable Schedules

Termination & Custom Fit

Every run is punched down, labeled at both ends and tested to the selected TIA standard with a Fluke Networks certification tester, so you receive a pass or fail report for each permanent link or channel instead of a promise. Wall plates, surface-mount fits, floor boxes and patch cords are made to suit the room rather than the catalog.

  • Standards-Based Certification on Fluke Networks Testers, with Saved Reports
  • Labeling to ANSI/TIA-606 Administration Practice
  • Jacks, Wall Plates and Patch Panels
  • Custom-Length Patch Cords

Server Room & Rack Deployments

Racks are assembled, leveled and anchored, then dressed with cable trays, vertical managers and labeled PDUs so airflow stays clear and every port is traceable. The room is laid out for service access as well as for the day-one install.

  • Rack and Cabinet Assembly with Floor Anchoring
  • Overhead Cable Tray and Ladder Rack
  • Metered and Switched PDU Installation
  • Airflow Management and Hot/Cold Aisle Layout

Commercial and Residential Electrical

Branch circuits, panelboard upgrades and feeder work for commercial and residential buildings, including dedicated power for server rooms and IDFs, performed by licensed, bonded electricians employed directly by ACG and coordinated with the low-voltage crew. Load calculations and equipment-room work follow the National Electrical Code (NEC) as adopted in Utah, with breaker schedules, panel directories and grounding documented so the room can grow without tripping a breaker.

  • Commercial and Residential Branch Circuits and Panelboards
  • Dedicated Power for Rack and IDF Equipment
  • NEC Load Calculations, Bonding and Grounding (TIA-607)
  • UPS, PDU and Automatic Transfer Switch Coordination

Enterprise Workplace AV & Collaboration Systems

Commercial video conferencing, digital signage and smart boardroom setups engineered as part of the building rather than bolted on afterward. Displays, DSP audio, cameras and room control are cabled, powered and commissioned alongside the network that carries them.

  • Video Conferencing Rooms for Teams, Zoom and Google Meet
  • Digital Signage Networks and Content Players
  • Smart Boardroom Control and Room Scheduling Panels
  • Ceiling Microphones, DSP Audio and Speakers
  • Video Conferencing
  • Digital Signage
  • Smart Boardrooms

Low-Voltage Security & Access Control

IP cameras, door access control, intercoms and alarm integration are cabled and powered as part of the building network instead of as a separate system nobody owns. Devices sit on their own VLAN, recordings stay on an NVR or storage you control, and every door controller and camera is documented.

  • IP Video Surveillance with On-Site Recording
  • Badge and Keypad Door Access Control
  • Intercom and Visitor Entry
  • PoE Power Budgeting (IEEE 802.3at/bt) and VLAN Segmentation
  • Video Surveillance
  • Access Control
  • Intercom